PS-3 Power Supply

DC power supply eliminates batteries in Oil Alert detectors - ideal for large installations where accessibility to Oil Alert is inconvenient or battery operation is not acceptable. Operates up to 24 Oil Alert detectors, wiring instructions furnished. Internal self-recharging battery provides back up power to system in event of line power failure or power cord removal. UL Listed input transformer. Flashing LED indicating power to Oil Alerts. Large screw-type terminal blocks at rear of enclosure for convenient wiring. Connection to Oil Alerts is made by means of wire nuts. Short circuit, overload and over voltage protected. Rugged attractive enclosure 8-1/2"W x 9-1/2"D x 2-1/2"H.

AD-5 Auto-Dialer

Auto-Dialer can call up to 4 phone numbers, including pagers for off site indication of activating Oil Alert detectors. Requires standard phone line with RJ-11 jack and power outlet. The AD-5 can be activated by the OA-5 or any Series 2100 Monitor, via relay input. Rugged attractive enclosure 8-1/2"W x 9-1/2"D x 2-1/2"H.

SM-2 Sensing Modules

Two pack of replacement Oil Alert Sensing Modules.

9V Battery

Industrial type, non-rechargeable, 9V Alkaline battery.

RA-WM Remote Alarm

Used for additional remote indication of liquid leakage. Compatible with OA-5 Oil Alert Detectors. Unit is surface wall mounted. Dimensions- 6"H x 3"W x 2"D . UL Listed input transformer. Input- Normally Open Contact from OA-5. 10mm LED indicator and 85db Audible Alarm w/silence switch.

Voltage Module

Rather than battery power it may be desirable to power Oil Alerts with your 12 or 24v AC or DC (or any voltage in between). A Voltage Module will be required for each detector in this application. The Voltage Module snaps into the Oil Alert and will convert your voltage to 9vdc as required. Model- VOLTAGE MODULE.

PR-WM Power Relay

Used to control high powered equipment such as pumps, motors and solenoids from an OA-5 Oil Alert Detector. Unit is surface wall mounted in a NEMA 4x nonmetallic encloser. Dimensions- 5.5" H x 3" W x 2.6" D. Unit will power up to 2 Oil Alert detectors Model OA- 5. UL Listed input transformer. Input:- Normally Open Contact from OA-5. Output: SPDT Relay Contact ( Form C) Rated - 120VAC @ 20 Amps. Large screw-type terminal blocks inside enclosure for convenient wiring. Connection to Oil Alerts is made by means of wire nuts. Power ON LED, Relay Activated LED.

Wire and Cable

TYPE "D" cable: Signal/Power wire - 3 conductor, stranded #22 AWG. with vinyl jacket. 0.150" O.D. For use with all Series 2100 systems.

TYPE "B" cable: Signal/Power wire - 2 conductor Twisted pair, stranded #22 AWG. with vinyl jacket. For use in PS-3 power runs and RA-WM signal runs less than 500'.

POWER WIRE #18: Power wire - 2 conductor twisted pair, stranded #18AWG. with vinyl jacket. 0.226" O.D. For PS-3 power runs and RA-WM signal runs between 500' and 2500'.

SERIES 2100: Monitored systems

The Series 2100 is an early warning leak detection system utilizing the latest line of Dorlen Products remote monitors and compatible OA-2100 Oil Alert detectors. All Series 2100 Monitors Monitor and Power the connected OA-2100 Oil Alerts. Learn more about oil sensor remote monitoring.